 MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
DESCRIPTION/FEATURES
* High-breakdown-voltage output port ......................................... 26
* Segment output ............................................ 8 to 18 * Digit output ................................................... 7 to 10 (Ports P0 to P7 are also used as ordinary output ports) * Output breakdown .................................. Vcc - 45 V * Output current .................. -18 mA (DIG0 to DIG17), -7 mA (SEG0 to SEG7) * Pull-down resistor ........................................ build-in * Dimmer switch ............................................ 4 levels A-D converter ................................................... 8-bit ! 6 channels * Absolute accuracy ....................................... 3 LSB
* Serial I/O ..................................... 4 (CS controller, external clock)
* Noise filter .................................................... build-in (in serial input pin and clock pin, 2 MHz sampling) * FLD display data ............................................. input * A-D conversion data ..................................... output * Command ....................................................... input Package ................................................................. 44P6N/44P6X Oscillating circuit ........... RC oscillating cirucit (external capacitor) * Oscillating frequency ..................................... 4 MHz Power source voltage .................................................. 4.0 to 5.5 V
* * *
*
PIN CONFIGURATION (TOP VIEW)
DIG15/SEG10
DIG14/SEG11
DIG13/SEG12 DIG12/SEG13
DIG11/SEG14
DIG10/SEG15
DIG9/SEG16
DIG8/SEG17
DIG7/P7 25
DIG6/P6 24
33
32
31
30
29
28
27
26
DIG16/SEG9 DIG17/SEG8 SEG7 SEG6 SEG5 SEG4 SEG3 SEG2 SEG1 SEG0 VDD
23
DIG5/P5
34 35 36 37 38 39 40 41 42 43 44
1 2 3 4 5 6 7 8 9 10 11
22 21 20 19 18 17 16 15 14 13 12
DIG4/P4 DIG3/P3 DIG2/P2 DIG1/P1 DIG0/P0 VEE VEE SCLK SOUT SIN CS
M35500AFP M35500BGP
VDD
VSS
XIN
RESET AN5
AN4
AN3
AN2
AN1
Package type: 44P6N-A/44P6X
Fig. 1. Pin configuration of M35500AFP/BGP
XOUT
AN0
1
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
FUNCTIONAL BLOCK
DIG8/SEG17 - DIG17/SEG8
SEG7 - SEG0
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43
DIG7/P7 25 DIG6/P6 24 DIG5/P5 23 DIG4/P4 22 DIG3/P3 21 DIG2/P2 20 DIG1/P1 19 DIG0/P0 18 VEE 17 VEE 16 Memory address Display RAM Transfer counter Mode register Display control circuit
FUNCTIONAL BLOCK DIAGRAM (Package: 44P6N-A)
Command analytic circuit
Byte end
CS 12 SIN 13 SOUT 14 SCLK 15 VDD 44 VDD 1 VSS 3 RESET 5
2 4 6 7 8 9 10 11
Noise filter Noise filter Trigger Clock generating circuit Selector/A-D control circuit
Serial I/O
A-D
XOUT
XIN
AN5 - AN0
Fig. 2. Functional block diagram
2
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
PIN DESCRIPTION
Table. 1. Pin description Pin VCC, VSS VEE XIN XOUT
______
Name Power source Pull-down power source Clock input Clock output
______
Input
Output
Function * Apply voltage of 5 V to VCC, and 0 V to VSS. * Applies voltage supplied to pull-down resistors.
Input Output CMOS input CMOS input CMOS input Noise filter N-channel open-drain CMOS input Noise filter P-channel open-drain P-channel open-drain P-channel open-drain
* RC oscillator pins for system clock.
RESET
____
RESET input Chip select Serial clock Serial output Serial input Digit/Port Digit/Segment Segment
* Reset input pin for active "L". * Internal pull-up resistors connected between the RESET and VCC pins. * Serial transfer is possible by inputting "L" signal. * Clock for serial transfer is input. * Read a clock twice with 2 MHz sampling clock and judge if it is a noise or not. * Serial data is output. * During reset it is in high-impedance state. * Serial data is input. * Read a clock twice with 2 MHz sampling clock and judge if it is a noise or not. * Pin for ordinary output or digit output. * At reset this port is set to VEE level through a pull-down resistor. * Pin for digit output or segment output. * At reset this port is set to VEE level through a pull-down resistor. * Pin for segment output. * At reset this port is set to VEE level through a pull-down resistor.
CS SCLK SOUT SIN DIG0/P0 - DIG7/P7 DIG8/SEG17 - DIG17/SEG8 SEG0 - SEG7
PORT BLOCK
(1) Digit/Port pin Digit/Segment pin Shift signal from high-order Dimmer signal (Note) Data bus Segment data
latch V
(4) SOUT pin
SOUT signal
Shift signal to low-order (2) Digit pin Shift signal from high-order Dimmer signal (Note)
latch
(5) CS pin VEE CS input
Noise filter
V
(6) SIN, SCLK pin Serial input Serial clock input
Noise filter
Shift signal to low-order
VEE (7) A-D input
(3) Segment pin Dimmer signal (Note) Segment data
latch V
A-D conversion input
VEE
V High-breakdown-voltage P-channel transistor Note: Dimmer signal is for setting the Toff time.
Fig. 3. Port block diagram
3
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
COMMAND STYLE
b7 Display data setting (Command 0) 1
b6 1
b5 1
b4 --
b3
b2
b1
b0
Number of segment setting 0 0 : 16 or less 0 1 : 17 or more Number of digit setting 00:7 01:8 10:9 1 1 : 10 Display state setting (Command 1) 1 1 0 -- -- Display ON or OFF setting 1 : ON 0 : OFF Display duty setting 1 1 : 15/16 1 0 : 14/16 0 1 : 6/16 0 0 : 5/16 Digit selection (Command 2) 1 0 1 -- Digit start pin setting 0 0 0 0 : D17 0 0 0 1 : D16 0 0 1 0 : D15 0 0 1 1 : D14 0 1 0 0 : D13 0 1 0 1 : D12 0 1 1 0 : D11 0 1 1 1 : D10 1 0 0 0 : D9 1 0 0 1 : D8 1 0 1 0 : D7 Port data setting (Command 3) 1 0 0 P3 - P0/P7 - P4 output data Port selection (Note) 0 : P3 - P0 1 : P7 - P4
Note: When a digit or a port has to be selected, a digit output is selected for having higher priority.
Fig. 4. Command style
4
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
SERIAL I/O PROTOCOL
Byte protocol CS
CLK b0 b1 b2 b3 b4 b5 b6 b7
SIN
SOUT
X
b0
b1
b2
b3
b4
b5
b6
b7
Note: SOUT is in high-impedance state during CS signal is "H".
Command protocol Display data setting (Command 0) CS CLK SIN SOUT
Command 0 Data 1 Data 2 Data i
X
X
A-D data 0
A-D data j
Note 1: The serial data which is transmitted after executing command 0 is recognized as a display data. "A-D data 6 or more" data is defined as an undefined "X". Note 2: Set the CS signal to "H" level after transferring a display data.
Other setting except display data setting (Command 1 to 3)
CS CLK SIN SOUT
Command
X
Fig. 5. Serial I/O protocol
5
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
SERIAL COMMUNICATION FORMAT (DISPLAY DATA, A-D OUTPUT)
17 or more segments (3-byte transfer)
CS CLK SIN
Command 0 SEG 0-7 SEG 8-15 DIG n SEG 16-17 SEG 0-7 SEG 8-15 SEG 16-17 SEG 0-7 SEG SEG 8-15 16-17 DIG n-2 SEG 0-7 SEG 8-15 DIG 0 SEG 16-17
DIG n-1
SOUT
X
X
AD 0
AD 1
AD 2
AD 3
AD 4
AD 5
X
X
X
X
X
AD valid data
Note: 2 bytes "X" data is output before outputting AD valid data. 16 or less segments (2-byte transfer)
CS CLK SIN
Command 0 SEG 0-7 SEG 8-15 SEG 0-7 SEG 8-15 SEG 0-7 SEG 8-15 SEG 0-7 SEG 8-15 SEG 0-7 SEG 0-7 SEG 8-15
DIG n
DIG n-1
DIG n-2
DIG n-3
DIG 0
SOUT
X
X
AD 0
AD 1
AD 2
AD 3
AD 4
AD 5
X
X
X
X
X
AD valid data
Note: 2 bytes "X" data is output before outputting AD valid data. 8 or less segments (2-byte transfer)
CS
CLK SIN
Command 0 SEG dummy SEG dummy SEG dummy SEG dummy SEG 0-7 0-7 0-7 0-7 0-7 data data data data DIG n DIG n-1 DIG n-2 DIG n-3 SEG dummy 0-7 data DIG 0
SOUT
X
X
AD 0
AD 1
AD 2
AD 3
AD 4
AD 5
X
X
X
X
X
AD valid data
Note: 2 bytes "X" data is output before outputting AD valid data.
Fig. 6. Serial communication format
6
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
FLD DISPLAY TIMING
Gn
G n-1
G1 Segment output
Tdisp
Tscan = 0ns
Digit Tdisp = 384 s (oscillation frequency f(X IN) = 4.0 MHz) Toff= 264 s ( 5/16 ! Tdisp) 240 s ( 6/16 ! Tdisp) 48 s (14/16 ! Tdisp) 24 s (15/16 ! Tdisp) Tdisp
Segment Toff
Fig. 7. FLD display timing diagram
SEGMENT/DIGIT SETTING EXAMPLE
PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 DIG SEG SEG0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 Grid :7 Segment : 8 S1 S2 S3 S4 S5 S6 S7 S8 G7 G6 G5 G4 G3 G2 G1 Grid : 10 Grid : 10 Grid :7 Segment : 8 Segment : 16 Segment : 18 S1 S1 S1 S2 S2 S2 S3 S3 S3 S4 S4 S4 S5 S5 S5 S6 S6 S6 S7 S7 S7 S8 S8 S8 G10 S9 S9 G9 S10 S10 G8 S11 S11 G7 S12 S12 G6 S13 S13 G5 S14 S14 G4 S15 S15 G3 S16 S16 G2 G10 S17 G1 G9 S18 G8 G7 G7 G6 G6 G5 G5 G4 G4 G3 G3 G2 G2 G1 G1
P7 P6 P5 P4 P3 P2 P1 P0
DIG17 DIG16 DIG15 DIG14 DIG13 DIG12 DIG11 DIG10 DIG9 DIG8 DIG7 DIG6 DIG5 DIG4 DIG3 DIG2 DIG1 DIG0
Fig. 8. Segment/Digit setting example
7
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
BIT ALLOCATION FOR DISPLAY RAM
ADDRESS 0916 0A16 0B16 0D16 0E16 0F16 1116 1216 1316 1516 1616 1716 1916 1A16 1B16 1D16 1E16 1F16 2116 2216 2316 2516 2616 2716 2916 2A16 2B16 2D16 2E16 2F16
b7 b0
SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 9 8 15 14 13 12 11 10 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0 SEG SEG 17 16 SEG SEG SEG SEG SEG SEG SEG SEG 15 14 13 12 11 10 9 8 SEG SEG SEG SEG SEG SEG SEG SEG 7 6 5 4 3 2 1 0
Digit0
Digit1
Digit2
Digit3
Digit4
Digit5
Digit6
Digit7
Digit8
Digit9
Fig. 9. Bit allocation for display RAM
8
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
RESET CIRCUIT
To reset the controller, the RESET pin should be held at a "L" level for 2 s or more. Then the RESET pin is returned to an "H" level (the power source voltage should be between 4.0 V and 5.5 V, and XIN oscillation is stable), reset is released. Make sure that the reset input voltage is 0.5 V or less for 4.0 V of VCC.
Poweron
(Note) RESET VCC 0V
0V
0.2VCC
Note. Reset release voltage: VCC = 4.0 V
Fig. 10. Reset circuit example
CLOCK GENERATING CIRCUIT
Oscillating circuit is built up by connecting pins XIN and XOUT as short as possible and connecting a capacitor between pins XIN (XOUT) and VSS. When supplying a clock externally, input it to XIN pin and leave XOUT pin open.
XIN
XOUT
XIN
XOUT
External oscillation circuit
Open
COSC
VCC VSS
Fig. 11. RC generating circuit
Fig. 12. External clock input circuit
HANDLING OF UNUSED PINS
Handle unused pins as the follow. Table. 2. Handling of unused pins Pin Segment Digit Analog input Open Open Connect to VCC or VSS through a resistor. Handling
9
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
ABSOLUTE MAXIMUM RATINGS
Symbol VCC VEE VI VI VI VO Parameter Power source voltage Pull-down power source voltage Input voltage AN0 - AN5 Input voltage CS, SIN, SCLK Input voltage RESET Output voltage DIG0 - DIG17 SEG0 - SEG17 Conditions * All voltage are based on VSS. * Output transistors are cut off. Ratings -0.3 to 7.0 VCC-45 to VCC+0.3 -0.3 to VCC+0.3 -0.3 to VCC+0.3 -0.3 to VCC+0.3 VCC-45 to VCC+0.3 Unit V V V V V
* All voltage are based on VSS. * Output transistors are cut off. * A waveform: 450 s or more frequency and 30 s or less pulse width. * Connect only capacitor load (CL = 200pF). * All voltage are based on VSS. * Output transistors are cut off. Ta = 25 C
VCC-50 to VCC+0.3
V
VO
Output voltage
SOUT
-0.3 to VCC+0.3 600 -20 to 85 -40 to 125
V mW C C
Pd Topr Tstg
Power dissipation Operating temperature Storage temperature
RECOMMENDED OPERATING CONDITIONS
Symbol VCC VSS VEE VIH VIH VIL VIL Parameter Power source voltage Power source voltage Pull-down power source voltage "H" input voltage CS, SIN, SCLK "H" input voltage RESET "L" input voltage CS, SIN, SCLK "L" input voltage RESET
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Min. 4.0 VCC-38 0.75VCC 0.8VCC 0 0 Limits Typ. 5.0 0 Max. 5.5 VCC VCC VCC 0.25VCC 0.2VCC Unit V V V V V V V
RECOMMENDED OPERATING CONDITIONS
Symbol IOH(peak) IOH(avg) IOH(peak) IOH(peak) IOL(peak) IOH(avg) IOH(avg) IOL(avg) f(XIN) f(SCLK) Parameter
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Min. (Note 1) (Note 2) (Note 2) (Note 3) (Note 3) (Note 4) 4.0 250 Limits Typ. Max. -240 -120 -40 -20 10 -18 -7 5.0 5.2 Unit mA mA mA mA mA mA mA mA MHz kHz
"H" total peak output current DIG0 - DIG17, SEG0 - SEG17 "H" total peak output current DIG0 - DIG17, SEG0 - SEG17 "H" peak output current DIG0 - DIG17 "H" peak output current SEG0 - SEG7 "L" peak output current SOUT "H" peak output current DIG0 - DIG17 "H" peak output current SEG0 - SEG7 "L" peak output current SOUT Main clock input oscillation frequency Serial I/O external clock frequency
Notes 1: The total output current is the sum of all the currents flowing through all the applicable ports. The total average current is an average value measured over 100 ms. The total peak current is the peak value of all the currents. 2: The peak output current is the peak current flowing in each port. 3: The average output current is an average value measured over 100 ms. 4: When the oscillation frequency has a 50 % duty cycle.
10
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
ELECTRICAL CHARACTERISTICS
Symbol VOH VOL VT+ -- VT- IIH Parameter "H" output voltage "L" output voltage Hysteresis "H" input voltage
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Test conditions IOH = -18 mA IOH = -7 mA IOL = 5 mA VCC = 5.0 V VI = VCC 4.0 VI = VSS -150 -4.0 VEE = VCC-36 V VOL = VCC Output transistors "off" VEE = VCC-38 V VOL = VCC-38 V Output transistors "off" 250 500 750 -5.0 Min. VCC-2.0 VCC-2.0 Limits Typ. Max. Unit V V V V V A A A A A A A
IIL
"L" input voltage
ILOAD
Output load current
DIG output SEG output SOUT SIN, SCLK, CS RESET, XIN SIN, SCLK, CS RESET XIN SIN, SCLK, CS RESET XIN DIG0 - DIG17 SEG0 - SEG17 DIG0 - DIG17 SEG0 - SEG17
2.0 0.5 0.5 5.0 5.0
ILEAK
Output leakage current
-10
A
ELECTRICAL CHARACTERISTICS
Symbol VRAM ICC Parameter RAM hold voltage Power source current
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Test conditions When clock is stopped VCC = 5 V, f(XIN) = 4.2 MHz Output transistors "off" at A-D converter operating Min. 2.0 Limits Typ. Max. 5.5 1.0 Unit V mA
0.5
A-D CONVERTER CHARACTERISTICS
Symbol -- -- Tconv VIA IIA RLADDER Parameter
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Test conditions Min. Limits Typ. Max. 8 3 100 VCC 5.0 Unit Bits LSB tc(XIN) V A k
Resolution Absolute accuracy (excluding quantization error) Conversion time Analog input voltage Analog port input current Ladder resistor
VCC = 5.12 V 0 0.5 35
11
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
TIMING REQUIREMENTS
Symbol tw(RESET) tc(XIN) twH(XIN) twL(XIN) tc(SCLK) twH(SCLK) twL(SCLK) tsu(SIN-SCLK) th(SCLK-SIN) tsu(CS) th(CS) tre(SCLK)
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Parameter Min. 2 238 60 60 5 2 3 2 3 50 tc(XIN) 50 tc(XIN) 50 tc(XIN) Limits Typ. Max. Unit s ns ns ns CLKs CLKs CLKs CLKs CLKs ns ns ns
Reset input "L" pulse width Main clock input cycle time (XIN input) Main clock input "H" pulse width Main clock input "L" pulse width Serial clock input cycle time (Note) Serial clock input "H" pulse width (Note) Serial clock input "L" pulse width (Note) Serial input setup time (Note) Serial input hold time (Note) Serial input setup time Serial input hold time Serial clock interval time
Note: The unit means a number of noise filter sampling clock (2 ! tc(XIN)).
SWITCHING CHARACTERISTICS
Symbol td(SCLK-SOUT) tv(SCLK-SOUT) tr(Pch) COSC Parameter
(VCC = 4.0 to 5.5 V, Ta = -20 to 85 C, unless otherwise noted) Test conditions Min. 2 CL = 100pF VEE = VCC-36 V 1.8 22 Limits Typ. Max. 3 3 Unit CLKs CLKs s pF
Serial I/O output delay time (Note 1) Serial I/O output valid time High-breakdown-voltage P-channel open-drain output rising time External capacitor size (Note 2)
Note 1: The unit means a number of noise filter sampling clock (2 ! tc(XIN)). 2: An external capacitor size varies with a mounted condition.
Measuring condition: Ta = 25 C, VCC = 5.0 V 8.0
Frequency f(XIN) [MHz]
7.0 6.0 5.0 4.0 3.0 2.0 10
20
30
40
50
60
70
80
90
100
External capacitor size COSC [pF]
Fig. 13. Standard characteristic example of f(XIN)-COSC
12
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
Serial I/O clock output port
P-channel output port
RL
CL VEE
CL
Fig. 14. Output switching characteristics measurement circuit diagram
tw(RESET)
RESET
0.2VCC
0.8VCC
CS SCLK
tsu(CS) trec(SCLK) th(CS)
tC(SCLK) twL(SCLK) twH(SCLK) 0.8VCC th(SCLK-SIN)
SCLK
0.2VCC tsu(SIN-SCLK)
SIN
td(SCLK-SOUT)
0.8VCC 0.2VCC tv(SCLK-SOUT)
SOUT
Fig. 15. Timing diagram
13
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
PACKAGE OUTLINE
44P6N-A
EIAJ Package Code QFP44-P-1010-0.80 HD JEDEC Code - Weight(g) 0.59 Lead Material Alloy 42
Plastic 44pin 10!10mm body QFP
MD e D
44 34
1
33
b2
I2 Recommended Mount Pad Symbol A A1 A2 b c D E e HD HE L L1 x y b2 I2 MD ME Dimension in Millimeters Min Nom Max - - 3.05 0.1 0.2 0 - - 2.8 0.3 0.35 0.45 0.13 0.15 0.2 9.8 10.0 10.2 9.8 10.0 10.2 - 0.8 - 12.5 12.8 13.1 12.5 12.8 13.1 0.4 0.6 0.8 1.4 - - - - 0.2 - - 0.1 - 0 10 - - 0.5 1.3 - - 10.6 - - - - 10.6 HE E
11
23
12
22
A L1
F A1 e
b
A2
x
M
y
L Detail F
14
c
ME
MITSUBISHI
M35500AFP/BGP
FLD(VFD) CONTROLLER
44P6X
EIAJ Package Code QFP44-P-1010-0.80 JEDEC Code - HD Weight(g) - Lead Material Cu Alloy
Plastic 44pin 10!10mm body QFP
MD
e
44
34
1
33
b2
I2 Recommended Mount Pad Symbol A A1 A2 b c D E e HD HE L L1 x y b2 I2 MD ME Dimension in Millimeters Min Nom Max 2.3 - - 0 0.2 0.1 2.0 - - 0.3 0.375 0.45 0.15 0.175 0.2 9.9 10.0 10.1 9.9 10.0 10.1 0.8 - - 12.5 12.8 13.1 12.8 13.1 12.5 0.4 0.6 0.8 1.4 - - - - 0.2 0.1 - - 0 10 - 0.5 - - 1.3 - - 10.6 - - 10.6 - -
HE E
11
23
12
22
A L1
e y
b
F x
M
A2
A1
L Detail F
Keep safety first in your circuit designs!
* Mitsubishi Electric Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non-flammable material or (iii) prevention against any malfunction or mishap.
Notes regarding these materials
* * * These materials are intended as a reference to assist our customers in the selection of the Mitsubishi semiconductor product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Mitsubishi Electric Corporation or a third party. Mitsubishi Electric Corporation assumes no responsibility for any damage, or infringement of any third-party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Mitsubishi Electric Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Mitsubishi Electric Corporation by various means, including the Mitsubishi Semiconductor home page (http://www.mitsubishichips.com). When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability or other loss resulting from the information contained herein. Mitsubishi Electric Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use. The prior written approval of Mitsubishi Electric Corporation is necessary to reprint or reproduce in whole or in part these materials. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited. Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for further details on these materials or the products contained therein.
* *
* *
*
(c) 2000 MITSUBISHI ELECTRIC CORP. New publication, effective Mar. 2000. Specifications subject to change without notice.
c
ME
D
REVISION HISTORY
Rev. No. 1.0 2.0 First Edition; As M35500AFP/AGP The followings are updated: Product M35500AGP is switched to M35500BGP. Page 1: Oscillating circuit.....RC oscillating... Page 3, Table 1: RC oscillator Page 9: Fig. 11. RC generating circuit
M35500AFP/BGP DATA SHEET
Revision Description Rev. date 11/15/97 01/07/00
Page 12, TIMING REQUIREMENTS: Limits of tc(SCLK) and twL(SCLK) Page 12, SWITCHING CHARACTERISTICS: Limits and Unit of tv(SCLK-SOUT) 2.1 Page 15: The 44P6X package outline is added. 03/09/00
(1/1)


▲Up To Search▲   

 
Price & Availability of M35500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X